17 Jan 2011 18:03
recomputing skew time when receiving an advertisement from the master in rfc 5798
Vladica Stanisic <vladica.stanisic <at> ericsson.com>
2011-01-17 17:03:37 GMT
2011-01-17 17:03:37 GMT
Based on the
state machine in rfc 5798 on page 23 steps 450-460 when vrrp is
in backup state and receives an advertisement there is no step to recompute the
skew time. While in steps 740-765 on page 25 when vrrp is a master and
receives an advertisement from some new master, it does recompute the
skew time in step 750.
Since skew time is part of master down
interval, shouldn't it be recomputed in both states when advertisement
is received from a master? Otherwise backup vrrp would continue to use skew
time that was computed based on
its configured value for advertisement
interval when initially router transitions to
backup.
Is this skew time recalculation implied in the backup
state or there should be an explicit step like in the master
case?